ELECTROCHEMISTRY

BOECO MULTIPARAMETER PH/ORP/

CONDUCTIVITY/TDS/SALINITY/RESISTIVITY/

TEMP.BENCH TOP METER

MODEL MBT-700

A

LCD with backlight showing pH / ORP or Conductivity / TDS / Salinity

and temperature readings

A

Two channel measurement allows measuring ph/ORP and Conductivity/TDS/

Salinity simultaneously

A

Up to 5 point calibration for pH and one point calibration for conductivity

A

Automatic or manual temperature compensation

A

Automatic buffer recognition (NIST and USA)

A

Bluetooth function to connect to smartphone, tablets or PC

A

When the unit is connected to a bluetooth device, the user can store data

into the device that meets GLP requirements.

The MBT-700 will be delivered incl. the following standard accessories:

1 x ATC probe, each 1 x 500 ml Buffer solution pH 4,01, pH 7,00

1 x AC adaptor, 1 x operating manual, 1 x flexible electrode holder

Specification:

Conductivity K = 0,475

Range

Resolution

Accuracy

0,0 to 475µS/cm

0,1µS/cm

±1% of reading +2µS/cm

475 to 4750µS/cm 1µS/cm

±1% of reading +5µS/cm

4,75 to 47,50mS/cm 0,01mS/cm

±1% of reading +0,05mS/cm

47,5 to 200,0mS/cm 0,1mS/cm

±2,5% of reading +0,5mS/cm

Conductivity K = 0,1

Range

Resolution

Accuracy

0.00 to 99,99µS/cm

0,01µS/cm

±1% of reading

100 to 200µS/cm 0,1µS/cm

±1% of reading

TDS

Range

Resolution

Accuracy

0,001mg/l to 200,0g/l

0,001/0,01/0,1/1mg/l ±0,5% Full Scale 0.01/0,1 g/l

Salinity

Range

Resolution

Accuracy

0.0 to 80,0 ppt

0,1 ppt

±0,5 % Full Scale

pH

Range

Resolution

Accuracy

-2,00 to 16,00 pH

0,01 pH

±0,01pH

mV

Range

Resolution

Accuracy

-1999,9 to 1999,9 mV

0,01 mV

±0,05% Full Scale

Temperature

Range

Resolution

Accuracy

-10,0 to 120,0°C

0,1°C

±0,4°C

pH buffer recognition:

US (1,68 4,01, 7,00, 10,01, 12,46 or

NIST (1,68, 4,00, 6,86, 9,18, 12,46)

mV Offset

±150 mV

pH calibration:

Up to 5 points

Conductivity Calibration:

1 point in each range

ATC

:

Auto / manual 0,0 to 120°C

Input impedance:

>3x10

12

ohms

Temperature sensor:

Thermistor, 10K ohms at 25°C

Memory:

When the unit is connected to a bluetooth

device, the user can store data into the

device that meets GLP requirements

pH electrode connection:

BNC

Conductivity cell connection:

6 PIN connector

Connectivity:

Bluetooth

Power requirement:

6 x 1,5 Volt AAA Alkaline batteries or

AC adaptor

Dimensions (LxWxH):

210 x 150 x 45 mm

Weight (net):

approx. 430 g

Code

Description

BOE 5197700

Bench Top pH/mV/Ion/Temp Meter, Model MBT-700,

AC adaptor, with standard accessories