Table of Contents Table of Contents
Previous Page  86 / 155 Next Page
Information
Show Menu
Previous Page 86 / 155 Next Page
Page Background

LABORATORY EQUIPMENT

86

CENTRIFUGES

Cat.-No.

run-up in sec

25

23

-4

run-down in sec.

2)

radius in mm

85

21,382

tubes per rotor

24

_

02023 02024

Lid 0E2040 incl.

n=15,000 min

-1

01420-B

Cat.-No.

with high

speeds we

recommend

to use

adapter

No. 02031

capacity in ml

1.5 0.5/0.8 0.2 /0.4 2.0

dimensions Ø x L mm

8x30/45

11x38

6x18/45 11x38

Angle rotor,

Cat. No. 01689-A

30-place,

n= 14,000 min

-1

max RCF 21,255

Angle rotor,

Cat. No. 01420-B

24-place,

n= 15,000 min

-1

,

max. RCF 21,382

4 Cyto rotors, suitable for U-320 and

U-320R are availble.

More informations are available in a

detailed cyto brochure.

1) Lowest attainable temp. in

precooled refrigerated

centrifuges at max. speed

2) Rund down in sec. braked

Please make sure not to

exceed the tubes max.

permissible RCF. for glass

tubes the max. RCF is 4,000

Lid Cat. No. 02425

with bio-containment

autoclavable

Lid (Cat. No. 02423

with bio-containment

autoclavable,

phenol-resistant

Optional lids for rotor 01420B

Cat.-No.

run-up in sec

35

31

0

run-down in sec.

2)

temperature °C

1)

radius in mm

97

RCF

21,255

tubes per rotor

30

_

02023 02024

n=14,000 min

-1

01689-A

Cat.-No.

with high

speeds we

recommend

to use

adapter

No. 02031

capacity in ml

1.5 0.5/0.8 0,2 /0.4 2.0

dimensions Ø x L mm

8x30/45

11x38

6x18/45 11x38

lid with bio-

containment incl.

30

Angle rotor,

Cat. No. 01620A

6-place,

n= 9,000 min

-1

,

max. RCF 9,418.

illustrated with adapter set

01646

Angle rotor,

Cat. No. 01613

12-place,

n= 6,000 min

-1

,

max. RCF 4,146

n=12.000 min

-1

run-up in sec

40

40

-2

run-down in sec.

2)

temperature °C

1)

radius in mm

82

103

93

RCF

16,582 15,455

13,201

tubes per rotor

12

12

01615

Cat.-No.

capacity in ml

5

15

dimensions Øx L mm

17 x 100

12/13x75

Cat.-No.

01054A

Angle rotor,

Cat. No. 01615

12-place,

n= 12,000 min

-1

,

max. RCF 16,582

Cat.-No.

run-up in sec

30

- 11

run-down in sec.

2)

temperature °C

1)

radius in mm

97

97

95

100

105

99

RCF

8,784 8,784 8,603 9,056

9,509

8,965

tubes per rotor

12

6

6

6

6

6

6

01448 01451 01447 01446

103

9,327

6

01463 –

01466 01646

n=9,000 min

-1

01620A

Cat.-No.

10

15

26 x 95 29 x 107

38 x 106

17 x 100

30

50

85

34 x 100

35 x 105

50/75

16 x 80

capacity in ml

dimensions Ø x L mm

17x 120 29 x 115

15

50

4)

5)

4) Adapter set,

6-place, for conical

50 ml tubes with

screw cap

5) Adapter set, 6-place, for conical 15 ml tubes with

screw cap. Remove 6 opposite carriers from rotor 01615

and replace them with adapters 01647.

run-up in sec

15

15

- 16

run-down in sec.

2)

temperature °C

1)

radius in mm

82

103

RCF

3,300

4,146

tubes per rotor

12

12

Cat.-No.

01054A

n=6,000 min

-1

01613

Cat.-No.

capacity in ml

5

dimensions Ø x L mm

12/13 x 75

15

15

17 x 100 17 x 120

6

01647

15

17 x 120

6

35°

Cat.-No.

run-up in sec

30

31

-11

run-down in sec.

2)

temperature °C

1)

radius in mm

142 145 139 142

RCF

3,215 3,283 3,147 3,215

tubes per rotor

32

32

8

32

01467 01467 01468 01467

139

3,147

8

01468

n=4,500 min

-1

01418

Cat.-No.

15

15

29 x 115 17 x 100

29 x 107

17 x 120

50

12

50

29 x115

50

17 x 100

capacity in ml

dimensions Ø x L mm

+ 00716

+ 00716

+ E2109 + E2110

Angle rotor,

Cat. No. 01418

8-place

N = 4.500 min

-1

max. RCF 3,305

illustrated with adapters

01467

146

3,305

32

01467

4-7

13 x 100

35°

35°

45°

RCF