SPECTROPHOTOMETERS

LABORATORY EQUIPMENT

Specification

S-200 Vis

S-220 UV/Vis

Wavelength Range:

320 to 1100nm

190 to 1000nm

Spectral Bandwidth:

6nm

5nm

Transmittance accuracy:

±0,5% T (NIST 930 Filter)

±1% T (NIST 930 Filter)

Transmittance repeatability:

0.2% T

0.5% T

Baseline flatness:

± 0.002 Abs (330-1090nm)

± 0.005 Abs (200-990nm)

Noise level:

0.001 Abs (500nm)

0.005 Abs (250 nm)

Baseline stability:

0.001 Abs/h (500nm)

0.005 Abs/h (250nm)

(after 2 hours warm up)

(after 2 hours warm up)

Stray light:

0.5% T

0.5% T

Wavelength controlled variable:

0.2nm

0,2nm

Wavelength accuracy:

± 1nm

± 2nm

Wavelength repeatability:

0,5nm

1nm

Wavelength scan speed:

2400nm/min

300nm/min

(0,2 sampling interval without filter)

(0,2 sampling interval without filter)

Wavelength move speed:

to any specified position within 1sec.

to any specified position within 1sec.

Absorbance:

-0.3 to 1.999

-0.3 to 1.999

Transmittance:

0 to 199.9%

0 to 199.9%

Spectrum Scanning:

Yes

Yes

Concentration:

-300 to 1999

-300 to 1999

Selectable Resolution:

1, 0.1, 0.01 or 0.001

1, 0.1, 0.01 or 0.001

Light source:

Tungsten Halogen lamp

pulsed-Xenon lamp

Detector:

Silicon photodiode

Display screen:

4,3 inches colorful touch LCD screen

Printer:

specified 80-column thermal printer (series port)

Metering mode:

Single beam

Memory:

SD card storage

Time Scan:

Graphical and calculated concentration value

Analysis:

Absorbance and wavelength of peaks and valleys

GLP:

Real time clock and calendar, Self Diagnosis

Size:

400 (W) x 280 (D) x 160 (H) mm

Power requirement:

AC, 100-240V, 50/60Hz

Power consumption:

100VA

Communication ports:

Serial printer port connects thermal printer

USB port connects PC

SD card port saves data and measurement methods

Accessories port connects and controls serval options

Weight:

4 kgs

TEST TUBE HOLDER

MICRO CUVETTE

HOLDER

THERMO PRINTER

LONG PATH

CUVETTE HOLDER

Accessories

Code

Description

BOE 8620005

Test tube holder (only for S-200)

BOE 8622004

Rectangular long-path cuvette holder for cuvettes

with 10, 20, 30, 50 and 100 mm path-length

BOE 8620003

Micro-cuvette holder, for cuvettes with centre

height of 15 mm

BOE 8620020

Flow cuvette holder, incl. quartz glass flow cuvette

of 150 µl

BOE 8620030

Set of Auto sample sipper and Flow cuvette holder

with quartz glass flow cuvette of 150 µl

BOE 8622040

Electronic thermostat (Peltier element) TC cuvette

holder (only for S-220, S-300)

BOE 8620050

Automatic 5 position cuvette holder

BOE 8620060

Thermo printer with 100V-240V AC power supply

BOE 8620001

Tungsten halogen lamp (S-200)

BOE 8622001

Xenon Lamp module (S-220, S-300)

BOE 8622070

UV DETECTIVE software to control and operate the

spectrophotometer on a PC. The versatile software

can control all spectrophotometer operations such as

photometry, wavelength scans, time scans and more

Further functions include storage of methods

programs, saving of numerical and graphical data,

downstream data processing, data transfer to

commercial spreadsheets such as Excel

®

and report

generation

FLOW CUVETTE

HOLDER

SAMPLE SIPPER

5-PLACE AUTO

SAMPLE HOLDER

ELECTRONIC THER-

MOSTAT HOLDER